Yield Monitor Calibration
Calibrate a combine yield monitor for on-farm variety trials: weight, moisture, header height, flow delay and verification loads.
Why calibrate before every harvest
A yield monitor estimates weight from the flow of grain past a sensor, and it drifts with crop, moisture, ground speed and wear. Uncalibrated, a monitor can be off by 5 to 10 percent, a gap larger than the variety differences you are trying to measure.
Calibration steps
- Distance and header width: check the settings and measure the cutting width.
- Flow delay: set the lag between cutting and sensor reading so the yield maps align with the field.
- Weight: harvest at least 4 to 6 loads of different sizes and flow rates, such as full speed and slow speed, and weigh each on a certified scale or a calibrated grain cart.
- Enter the scale weight for each load following the monitor's procedure.
- Moisture: compare the on-board sensor with a verified meter and enter any offset.
- Header height: set the sensor so harvesting and lifted states are correct.
Verify
After calibration, harvest a test load of the crop in a typical field and compare monitor weight with scale weight. A difference under 1 to 3 percent is common for good practice. Recalibrate for each crop and whenever conditions change substantially, such as dry grain after wet.
Calibration log
| Load | Monitor weight (lb) | Scale weight (lb) | Error | Ground speed |
|---|---|---|---|---|
| 1 | 9,820 | 9,980 | -1.6% | 4 mph |
| 2 | 14,510 | 14,400 | +0.8% | 3 mph |
| 3 | 6,300 | 6,420 | -1.9% | 5 mph |
After the calibration weights are entered, rerun the check with a new load. Errors that remain positive at slow speed and negative at fast speed show a flow problem, and you may need to repeat the calibration across a wider range of flow rates. Save a copy of the calibration file from the monitor, and note the date, crop, variety and moisture. If you change combine or header, calibrate again.
Cleaning the data
Remove points from turns, overlaps, start-up and shut-down, and times when the header was lifted. Most monitor software offers filters. Summarize by strip, not by individual points.
Trial specific advice
| Issue | Remedy |
|---|---|
| Short strips cause end effects | Use long strips and discard the first and last 50 to 100 feet |
| Speed changes between plots | Keep speed steady, and note exceptions |
| Differing varieties in the tank | Clear the grain path between plots |
For the highest accuracy, weigh each strip on a weigh wagon or a scale cart and use the monitor only for mapping. Keep the calibration file with the trial notes. After harvest, treat the combine and yourself to farm.FM Farming.
Authoritative references
- USDA National Agricultural Statistics Service
- USDA NIFA Cooperative Extension
- USDA Agricultural Research Service
General guidance only. Check seed labels, pesticide labels and local recommendations with your land-grant Extension specialist.