Seed Variety Trials

Grain Moisture Meter Verification

Verify that your grain moisture meter is accurate by testing known samples and comparing with an elevator or lab.

A wrong meter ruins every comparison

A meter reading 1.5 points high on one hybrid and 0.5 on another changes both the adjusted yield and the drying cost estimate. If you do not check the meter, you do not know.

Annual check

  1. Collect samples of at least a quart from five to eight plots or fields spanning the moisture range you expect, such as 12 to 22 percent.
  2. Seal each sample in a bag or jar so moisture does not change, and bring them to room temperature.
  3. Test each with your meter, using the same fill method every time.
  4. Take the samples to your elevator, a state grain lab, or an Extension office, and ask for readings on their official instrument.
  5. Compare.

Record the comparison

SampleYour meterOfficialDifference
113.413.1+0.3
216.015.4+0.6
320.819.9+0.9

This meter reads higher as moisture rises. Apply a correction only if the pattern is consistent, and write the correction on the sheet. If the differences exceed about one point, have the meter serviced or replaced.

When to check and what to log

Check the meter at the start of every harvest, when you switch crops, after repairs and whenever readings seem odd. Keep a log with date, sample number, meter reading, official reading, grain temperature and the person who made the test. Over several seasons the log reveals whether your meter is drifting or whether one crop reads differently from another. If your meter has a calibration adjustment, change it only with the manufacturer's directions and log the old and new settings.

Handheld versus bench meters

Handheld probes measure a small sample and are affected by grain temperature and bulk density. Bench meters that weigh the sample are usually more consistent. For research trials where a one-point error matters, use a bench meter and take two readings.

Good habits

  • Use the correct crop setting, and recheck it if you switch crops.
  • Do not test hot grain straight from the combine. Let it cool.
  • Clean the cell and check the temperature reading.
  • Use fresh batteries and note the meter model and serial number.
  • Always use the same meter for all plots in one trial.

Sampling the combine hopper rather than the grain cart avoids mixing. Once the meter is confirmed, spend an evening on farm.FM Farming.

Authoritative references

General guidance only. Check seed labels, pesticide labels and local recommendations with your land-grant Extension specialist.